Recommended Load 48″ wide sheet – Over purlins & girts and rafters & studs

Load Chart & Bending Radius – Roof Purlin & Wall Girt Framing
( Bending Radius for both polycarbonate and Base & Cap )

Purlin Spacing 48″ 45″ 42″ 36″ 30″ 28″ Bending Radius
8mm Poly NA NA NA 20 lbs. 35 lbs. 40 lbs. 8 feet
10mm Poly NA NA 20 lbs. 35 lbs. 50 lbs. 60 lbs. 8 feet
16mm 3-wall 20 lbs. 30 lbs. 35 lbs. 60 lbs. 75 lbs. 90 lbs. 9 feet
Purlin Spacing 90″ 75″ 63″ 54″ 48″ 36″ Bending Radius
16mm X-wall NA NA 20 lbs. 35 lbs. 45 lbs. 80 lbs. 10 feet
25mm X-wall 20 lbs. 35 lbs. 50 lbs. 60 lbs. 80 lbs. 105 lbs. Do Not Bend

Outside of structure to center of 1st & framing member 48.5″.- Structural Load on snow & wind load
On-Center of framing members & Base is 49″.

Load Support & Blocking Placement when setting poly on vertically running Rafters & Studs
Outside of structure to center of 1st & framing member is 48.5″.- Structural Load on snow & wind load
On-Center of Intermediate framing members & Base is 49″

Thickness Rafter Spacing 20 lb. load 35 lb. load 45 lb. load 60 lb. load
8mm 49″ every 3 ft. every 2.5 ft. every 2.25 ft. every 2 ft.
10mm 49″ every 3.5 ft. every 3 ft. every 2.75 ft. every 2.25 ft.
16mm 3-wall 49″ every 4 ft. every 3.5 ft. every 3.25 ft. every 3 ft.
16mm X-wall 49″ every 5.5 ft. every 5 ft. every 4.5 ft. every 3.75 ft.
25mm X-wall 49″ every 7.5 ft. every 6.25 ft. every 5.25 ft. every 4.5 ft.

Outside of structure to center of 1st & framing member is 48.5″.- Structural Load on snow & wind load
On-Center of Intermediate framing members & Base is 24.5″
No spacers needed on blocking, but hold back 1/4″ from surface of poly. 25mm for 80 plus lb. load

Thickness Rafter Spacing 20 lb. load 35 lb. load 45 lb. load 60 lb. load
8mm 24-1/2″ every 6 ft. every 5 ft. every 4 ft. every 3 ft.
10mm Poly 24-1/2″ every 7 ft. every 6 ft. every 5 ft. every 4 ft.
16 & 25mm 3-wall 24-1/2″ not needed every 7 ft. every 6.5 ft. every 6 ft.
16mm X-Wall 24-1/2″ not needed every 9 ft. every 8 ft. every 7 ft.
25mm X-Wall 24-1/2″ not needed not needed not needed not needed

Heavy wind & snow loads

Thickness Rafter Spacing 80 lb. load 105 lb. load
16mm X-Wall 48 3/4″ to 49″ every 3.5 ft. every 2.5 ft.
16mm X-Wall 24 3/8″ to 24 1/2″ not needed every 4.5 ft.
25mm X-Wall 48 3/4″ to 49″ every 4.25 ft. every 4 ft.
25mm X-Wall 24 3/8″ to 24 1/2″ not needed not needed

Sheet must be supported on all 4 edges, minimum of 1/2″ of sheet bearing on Base or frame. When using sheets cut along width, and no longer have rib at edge, position so first rib supported by minimum of 1/2″. Also see Position & Attach Guidelines. Chart is poly. mfg. specs for selecting sheet thickness, rafter spacing and blocking placement to support loads on poly. Chart may be used for roof or wall design.

Local bldg. dept. provides snow & wind load for your area. Ability to support load factor of frame strength and poly. sheet rigidity. Follow chart above and poly. sheet will support load.